SCM3712 REFERENCE MANUAL 57
8.5.3.2. Request Service
Description
This command is used to know the area key version of the specified area and the service key version
of the specified service of FeliCa card
Format
CLA
INS
P1
P2
P3
Data
0xFF
0x42
Number of
services/areas
0x00
2 * P1
Service Code List /
Area Code List
Response
Data
SW1 SW2
8 bytes IDm + No. of Service or areas(n)
+ Service version or area version list (2*n)
0x90 0x00
8.5.3.3. Request response
Description
This command is used to know the current mode (Mode 0/1/2) of the FeliCa card
Format
CLA
INS
P1
P2
P3
Data
0xFF
0x44
0x00
0x00
0x00
-
Response
Data
SW1 SW2
8 bytes IDm + Mode
0x90 0x00
8.5.3.4. Read
Description
This command is used to read the record value of the specified service of the FeliCa card
Format
CLA
INS
P1
P2
P3
Data
0xFF
0x46
Number of
services
Number of
blocks
2*(P1 + P2)
Service Code List,
Block List
Response
Data
SW1 SW2
8 bytes IDm + Status Flag 1 + Status Flag
2 + No. of blocks(n) + Block data (n*16)
0x90 0x00